loading

Reducing EMI in buck converters



Abstract

Reducing Electromagnetic interference (EMI) in switch mode power supplies can be a challenge, because of the very high frequencies that are involved. Electrical components behave differently than expected, because the parasitic effects of the components often play an important role. This application note describes some basics of low voltage buck converter operation with respect to EMI, and provides some practical tips how to reduce EMI in the buck converter design.



1. Introduction

When designing a switch-mode converter, electromagnetic compliance is often tested in the later stages of the design phase. If EMI was not considered during the initial stage of the design, it can often be difficult or expensive to reduce EMI afterwards. The best way to ensure a smooth and optimal product design is to consider EMI in the beginning phase of the design. Component choice and layout considerations are crucial in obtaining good EMI performance from the start.



2. Sources of EMI in Buck converters

EMI radiation can be generated by two sources: Alternating electric field source (high impedance) or alternating magnetic field source (low impedance). Non-isolated DC/DC converters have relatively low impedance nodes and loops (much lower than the far-field impedance of 377Ω), so magnetic fields are generally the main radiation source in DC/DC buck converters.

Magnetic field radiation is caused by a high frequency current flowing in a small current loop. The current loop will emit high frequency magnetic field, which gradually transitions into electromagnetic field when the distance to the source exceeds 0.16λ (far field). The field strength of a small current loop is approximately :

Technical Document Image Preview

where f is the signal frequency in Hz, A is the loop area in m2, I is the current amplitude in the loop in Ampere, and R distance to the loop in meters.

As example, a 1cm2 current loop with 1mA current with 100MHz frequency at 3m distance generates a field strength of 4.4µV/m or 12.9dBµV.

Figure 1 below shows the approximate radiation of a 1cm2 current loop with 1mA current at 3m distance as a function of the frequency of the current. The green line shows the approximate EN55013 radiation limit for 3m distance.

loop radiation graph.JPG

Figure 1

From the figure, it can be seen that radiation of a 1cm2 loop with 1mA rms high frequency current will not easily exceed limits. The problem that often leads to exceeding the limits is when smaller loops excite bigger loops or wiring attached to the PCB starts radiating. These bigger loops or wires are much more effective antennas and will therefore have much higher contribution to total radiation.



3. Identifying current loops in a Buck converter

The DC/DC buck converter has two main loops where high AC currents flow as shown in figure 2.

When the high-side MOSFET Q1 is on, the current flows from supply via Q1 and L1 to the output capacitor and the load. The current flows back via ground to the input. The AC portion of the current will flow via the input and output capacitors. This current is shown in red color as I1 in figure 2.

When Q1 switches off, the inductor current will keep flowing in the same direction, and the synchronous rectifier MOSFET Q2 is switched on. The current flows via Q2, L1, load and output capacitor and back via ground to Q2. This loop is shown in blue as I2. Both I1 and I2 are discontinuous currents, meaning that they have sharp rising and falling edges at the beginning and end of the active time. These sharp edges have fast rise and fall times (high dI/dt). Therefore they have a lot of high frequency content.

Technical Document Image Preview

Figure 2 : Buck converter current loops

I1 and I2 share a common path from switch node to inductor to output capacitor to ground back to the source of Q2. The sum of I1 and I2 is a relatively smooth continuous saw-tooth waveform, which has less high frequency content due to the absence of high dI/dt edges.

From EMI radiation point of view, the current loop with the high dI/dt current is the shaded area A1 as shown in figure 3. This loop will generate the most high frequencies and should be considered the most critical loop for EMI in buck converters. The dI/dt of the current in area A2 is not nearly as high as in A1 and generally generates a lot less noise.

Buck current loops1.JPG

Figure 3

When setting up the PCB layout of a buck converter, shaded area A1 should be made as small as possible.

See chapter 7 for practical tips on layout.



4. Input and output filtering

In ideal case, the input and output capacitors would be very low impedance for the buck converter switching currents. But in practice, capacitors will have ESR and ESL, which increases the capacitor impedance and results in extra high frequency voltage drop across the capacitor. This voltage will induce currents in the supply input line and connections to the load, as shown in figure 4.

Buck current loops2.JPG

Figure 4

Due to the discontinuous nature of the buck converter input current and the fact that the supply lines to the converter are often quite long, the input loop A3 can radiate considerably or result in exceeding conducted emission levels in the conducted EMC measurements (150kHz ~ 30MHz band)

To reduce the voltage drop across Cin, use low ESR MLCC types and multiple capacitors of different size like 2x10µF 1206 and one 22n~100nF 0402 or 0603 size type close to the buck IC. To reduce the noise in the input loop, it is highly recommended to add extra L-C filtering in the input line. When using pure inductance for L2, it may be necessary to add the electrolytic capacitor C3 to damp any input supply ringing and ensure stable input supply.

To filter the output, also use multiple different size MLCC for Cout. Small 0603 or 0402 size 22nF~100nF capacitors can better block high frequency noise that may be coupled from switch node onto the output via the parasitic capacitance of the inductor L1. An additional HF bead will avoid the output loop from becoming an effective loop antenna. It should be noted that HF beads in the output can deteriorate the load transient response and load regulation. If the application load is critical in this respect, don’t use beads but place the converter as close as possible to the load, and minimize the loop area by using copper planes in the output.

Buck current loops3.JPG

Figure 5 : Buck converter input and output filtering



5. Reducing buck converter switching speed

If the radiation levels of the buck converter circuit still exceed requirement levels and layout or filtering cannot be improved, then reduction of the buck converter switching speed can help reducing the radiation levels. To understand the radiation reduction that can be achieved, let’s examine the frequency content of a discontinuous current pulse waveform.

Figure 6 left side shows the simplified current waveform as a trapezoidal wave with period TPERIOD, width TW and rise and fall times TRISE. The frequency domain will consist of the fundamental frequency and many upper harmonics. The relation between the pulse width, rise/fall times and amplitude of the upper harmonics can be derived via Fourier analysis and is shown in figure 6 right side.

Technical Document Image Preview

Figure 6 : Harmonic content of a pulse waveform

The figure 6 frequency values are based on an example with 800kHz switching signal with a pulse width of 320nsec and 10nsec rise and fall times. Radiated EMI problems often occur in the 50MHz~300MHz range, and it can be seen that increasing rise and fall times will shift the fR point to lower frequency, and the high frequencies will roll-off more quickly with 40dB/dec. In the lower frequency range, the impact of slower rise and fall times is quite limited.


Adding series resistor in bootstrap circuit.


The switching waveform rise time is determined by the switch-on speed of the high-side MOSFET Q1. Q1 is driven by a floating driver that is supplied via a bootstrap capacitor Cboot. In integrated buck ICs, C boot is charged via an internal regulator (normally 4~5V). See figure 7 left side.

Technical Document Image Preview

Figure 7 : Adding series resistor in bootstrap circuit

Increasing the rise time of the buck converter switch waveform and current pulse can be accomplished by slowing down switch-on speed of the high side MOSFET, which can be accomplished by adding a resistor Rboot in series with Cboot as shown in figure 7 right side. The value of Rboot depends on the size of the high side MOSFET. For most applications around 5~10Ω is used. For smaller (higher Rdson) MOSFETs, larger Rboot values are allowed. Too high values for Rboot may cause insufficient Cboot charging in high duty-cycle applications, or cause instabilities in the IC current sense. Slower MOSFET switch-on will also increase switch losses and reduce efficiency.

In designs were the MOSFETs are external, it is possible to add a series resistor in high-side MOSFET gate. This will increase the high-side MOSFET switch-on time and switch-off time.

When the high-side MOSFET Q1 is switched off, the inductor current will charge the parasitic output capacitance of Q1 and discharge the parasitic output capacitance of Q2 until the switch waveform goes below ground and activates the body diode of Q2. The falling time is therefore basically determined by the inductor peak current and the total parasitic capacitance at the switch node.

Figure 8 shows an example of the parasitic components of a buck converter IC in a typical layout.

IC parasitics.JPG

Figure 8

The parasitic capacitances are caused by the MOSFETs Coss and capacitance to substrate. The bonding wires from IC pins to silicon die will have some parasitic inductance. These parasitic components in combination with the PCB layout parasitic inductance and input filter capacitance ESL will cause high frequency ringing in the switching waveforms. When the MOSFET Q1 switches on, the ringing frequency in the positive edge is mostly determined by Coss Q2 and the total parasitic inductance in the MOSFET switching loop (LpVIN + LpGND + LpLAYOUT + ESLCIN).

When the MOSFET Q1 switches off, the ringing frequency in the falling edge is mostly determined by Coss Q1 and the parasitic inductance in the low-side MOSFET source to ground (LpGND).

Technical Document Image Preview

Figure 9

Figure 9 shows an example of a switching waveform with fast rise and fall times and positive edge and negative edge ringing. Due to the energy ½∙I2∙Lp stored in the parasitic inductance, the ringing amplitude will increase with load current. The frequency range will often be around 200~400MHz and results in high frequency EMI radiation. Excessive ringing often points to larger circuit parasitic inductance, and the layout should be checked for bigger loops or thin traces in Vin or ground. Component package can also influence ringing: bonding wire packages will perform worse than flip-chip packages due to the higher inductance of bonding wires compared to pillar bonds.


RC snubber damping


Adding an RC snubber can effectively damp out ringing, at the expense of increased switching losses.

The RC snubber should be placed as close as possible to the switch node and power ground. In buck converters with external MOSFETs, the RC snubber should be placed directly across the drain and source of the low side MOSFET. Figure 10 shows the placement of the RC snubber.

Technical Document Image Preview

Figure 10

The aim of the snubber resistor Rs is to add sufficient damping to the parasitic resonant LC circuit. The value for Rs depends on the desired damping and the parasitic L & C components of the circuit and is given by :

Technical Document Image Preview

where ξ is the damping factor. Normally ξ can range from 0.5 (slightly underdamped) to 1 (critically damped).

The values for parasitic Lp and Cp are normally not known, and can best be measured in the following way :

1. Measure the original ringing frequency fRING in the rising edge.

2. Add some small capacitance from switch node to ground, and watch the ringing frequency become lower. Keep adding capacitance until the ringing frequency is 50% of the original ringing frequency.

3. A 50% reduction in ringing frequency means that the total resonance capacitance is four times the original capacitance. The original capacitance Cp is therefore 1/3 of the added capacitance.

4. The parasitic inductance Lp can now be calculated by Technical Document Image Preview

The series capacitor Cs of the RC snubber needs to be large enough that the damping resistor can perform steady resonance damping during the circuit ringing. Too large values for the capacitor will increase power loss due to the charging and discharging of the capacitor each switch cycle. Normally Cs is chosen 3~4 times larger than the circuit parasitic capacitance.

Besides resonance damping, the RC snubber will also slightly increase rise and fall times of the switching waveform. However, the charging and discharging of the snubber capacitance will result in extra switching peak current spikes during switching transitions, which may increase EMI in lower frequency areas.

After placing the RC snubber, be sure to check the total power loss of the circuit : The converter efficiency will drop, especially at high switching frequency and high input voltages.


RL snubber damping


A less obvious way to damp ringing in the switching circuit is the addition of an RL snubber in series with the resonant circuit. The buck converter with RL snubber is shown in figure 11. The aim is to add a small amount of series resistance in the resonant circuit, sufficient to provide some damping. Due to the fact that the total resistance of the switching circuit is normally quite low, this damping resistor Rs can be low as well, in the order of 1Ω or less. The inductor Ls is chosen to provide low impedance at lower frequencies than the resonance, basically to short-circuit the damping resistor in the low frequency range. Since the ringing frequency is normally quite high, the required inductor can be small as well, in the order of a few nH, which can be achieved via a few mm of thin PCB trace, so it does not significantly increase the loop area. It is also possible to use a very small bead in parallel with Rs as substitution for Ls; in that case the bead must have low impedance at frequencies well below the resonance frequency, and must have sufficient current rating for the input RMS current.

snubber RL.JPG

Figure 11

The RL snubber can best be placed close to the power stage input node. One drawback of the RL snubber is that it creates impedance Rs in the switching loop the high frequency region. During the very fast switch transitions, the switch current pulse will create a short voltage glitch across Rs, resulting in a small voltage glitch on the power stage input node. If this VIN voltage glitch reaches too high or too low values, the power stage switching or IC operation may be affected. Be sure to check the voltage glitch on VIN node during maximum load switching when the RL snubber is added.



6. Practical example

In this chapter shows the effects of several aspects of buck converter design on EMI. We use RT7297CHZSP, a flexible 800kHz, 3A current mode buck converter in PSOP-8 package which is tested in a 12V – 3.3V/3A application. The schematic of the test setup is shown in figure 12.

Technical Document Image Preview

Figure 12

The test board was made in two versions : one with full copper ground plane and one without ground plane.

The board has several options like LC input filter, different input capacitor placement, Rboot and RC snubber option and output LC filter option. The test layout with the different options is shown in figure 13.

Technical Document Image Preview

Figure 13 : EMI test board

The test measurement setup is shown in figure 14.

Technical Document Image Preview

Figure 14

When the board under test is placed on the lab table, the PCB current loops and wiring will radiate HF energy to the environment.

This radiation finds its way back to the board as high frequency common mode current in the supply leads. See figure 15. The high frequency common mode current in the supply leads is basically the combined radiated field current from the board, and can be used as an indication of radiated emission when doing experiments.

Technical Document Image Preview

Figure 15 : Common mode current caused by field radiation

The input supply for the converter is provided by a 3S (~12V) Li-Ion battery, to be independent of other lab equipment. There is an electrolytic capacitor across the battery leads to eliminate resonances due to battery inductance.

The converter load is a 1Ω resistor in parallel with a 10µF MLCC capacitor. This provides a 3A load to the converter with low impedance for high frequencies.

The ground lead of the input line at the battery end is connected via 100Ω to the lab bench ground. This gives the circuit a ground reference, with impedance similar as the EMC measurement LISN network.

The self-made EMI current measuring tool (see chapter 8) can be placed in the supply input and output wires. In this report, we use an oscilloscope to view the measured HF current signal, which will show high frequency glitches during the converter switching transitions. For these repetitive switch signals, it is possible to let the oscilloscope calculate the FFT of the noise signal, to see the frequency content of the measured current. Although this is nowhere as accurate as a spectrum analyzer, it is still quite useful for experiments and judgment on a simple circuit.


Input capacitor placement


Experiment 1 : Place Cin far from the IC

The layout in figure 16 shows a bad placement of the input capacitor, resulting in a switching loop with lots of parasitic inductance. (The layout has some extra gap to increase the loop area)

Technical Document Image Preview

Figure 16

We first do a general check on radiated noise by measuring the common mode current in the input wires

Technical Document Image Preview

Figure 17 : Common mode current measurement in input wires

Figure 17 right side shows that the common mode current is extremely high and extends over a wide frequency band.

We can examine the source of the common mode current by using the loop antenna to search for radiated fields on the PCB. When the loop antenna tool is held above the input loop, the scope shows a lot of radiated noise in low and mid frequency range up to 200MHz above the Cin loop, see figure 18.

We also see that the switching waveform has a very big overshoot and ringing, actually exceeding IC voltage ratings. So the bad placement of the input capacitor gives both high radiation and big waveform ringing.

Technical Document Image Preview

Figure 18 : Measuring radiated field from big CIN loop on single sided PCB

If we do the same measurement on the board with a ground plane on bottom side, it can be seen that the radiation from the big Cin loop with the ground plane is much lower than with the single sided board. Switching ringing is also slightly lower in the board with the ground plane, see figure 19.

Technical Document Image Preview

Figure 19 : Big CIN loop on double sided PCB with ground plane

The HF magnetic field from the big loop creates eddy currents in the bottom ground plane which create a field in opposite direction that partly cancels the original magnetic field. The closer the ground plane to the loop, the more effective it will be.

Experiment 2 : Cin closer to the IC.

We continue with the single sided PCB, and place the Cin capacitor close to the IC, which results in a much smaller Cin loop. See figure 20.

Technical Document Image Preview

Figure 20 : Better placement of CIN

The switching overshoot and ringing is around 50% lower, and radiated emission has dropped around 10dB.

The frequency band extends now to 300MHz range.

Technical Document Image Preview

Figure 21

It is important to realize that the better placement of Cin will improve both switching waveform overshoot & ringing and reduce the HF radiation.

In RT7297CHZSP, the thermal pad is not connected to the die, so the layout copper connection to the thermal pad does not shorten the Cin loop. The high side and low side MOSFETs are connected via multiple bonding wires to the VIN and GND pin. So the shortest loop is via these two pins.

Technical Document Image Preview

Experiment 3 : Add an additional small 10nF capacitor directly between the IC VIN and GND pins.

Figure 22 shows the placement : The Cin loop is now basically determined by the IC pins, bonding wires and 0603 capacitor size.

Technical Document Image Preview

Figure 22

The switching waveform overshoot is virtually gone, but a lower frequency ringing has appeared.

The measurement loop has to be positioned closer to the PCB : The high frequency noise is gone, but there is a large peak in the low frequency area around 25MHz.

Technical Document Image Preview

Figure 23 : Adding single 10nF 0603 between ic GND and VIN pins

The low frequency resonance is a result of two capacitors in parallel in different loops with different resonances. This often happens during EMI trouble shooting, and the loops and resonances should be identified. In this case, the 10nF resonates with a 4nH parasitic inductance (~3mm conductor length), creating a 25MHz resonance. The resonant loop is the small 0603 capacitor with IC pins, bonding wire and layout traces, which make a loop with around 3mm length.

The solution can be found by adding a large 1206 22µF capacitor with slightly higher ESR in parallel to the small 10nF capacitor.

The layout with optimal Cin capacitor locations is shown in the layout of figure 24.

Technical Document Image Preview

Figure 24

With above solution, the single sided board switch waveform overshoot is virtually gone, and the radiated noise pick-up from loop antenna is also very low; the FFT waveform is mainly at the noise floor level.

Technical Document Image Preview

Figure 25 : Final solution with shortest CIN loop

If we now measure the common mode current in the input wire with the HF current probe, we see that the common mode noise has dropped a lot, more than 30dB at some frequencies when compared with the first measurement. This means that the total board radiation level is now quite low.

Technical Document Image Preview

Figure 26 : Final solution common mode measurement


Input supply wire filtering


The high frequency current in the input supply wire consists of both differential mode and common mode currents. Common mode noise can be reduced by minimizing the area of the high dI/dt current loops in the board layout. Input wire differential mode current has different source. It can be measured with the self-made current probe by passing the + and – wires through the core in opposite direction as shown in figure 27 below :

Technical Document Image Preview

Figure 27 : Differential mode current measurement

The differential current that we measure is caused by the buck converter pulsing input current passing through the input capacitors, causing a voltage drop across the capacitance and ESR of the input capacitor and layout ESL if it is included in the loop. This voltage drop results in a differential mode a current in the input supply wires.

It is possible to reduce this differential mode current by increasing the input capacitance, but it is much more effective to add a small LC filter in the input wire as shown in figure 28 right side.

Technical Document Image Preview

Figure 28 : Input filtering


Without extra input filter With input filter 10µF 1206 MLCC + 0603 bead 2A BLM18PG121SN1 With input filter 10µF 1206 MLCC + 1µH inductor LQH3NPN1R0 1.5A
Technical Document Image Preview

Figure 29

As can be seen from figure 29, adding a bead + capacitor will remove all high frequency except the 800kHz fundamental; Using a 1µH inductor + capacitor will remove all differential mode noise including fundamental.


Output wire filtering


When measuring the differential mode in the output supply, there is not much high frequency content, due to the continuous output current without high dI/dt. There is however considerable lower frequency noise up to around 30MHz. Most of the differential current in the output leads is caused by the converter inductor ripple current passing through the output capacitors, which also have some ESR. Adding an extra LC filter by means of bead and MLCC capacitor as shown in figure 30 will remove most of the differential noise.

Technical Document Image Preview

Figure 30 : Output filtering

Measuring differential mode current in the 3.3V output leads Without extra output filter With output filter 22µF 1206 MLCC + 0603 bead 4A BLM18SG700TN1
Technical Document Image Preview

Figure 31

Quite often, some inductor stray magnetic field is coupled into the output loop as well.

Shielded inductor types have low stray fields and will not easily couple into the output loop. But in case non-shielded or semi-shielded inductors are used, the output loop area to the load needs to be minimized to avoid stray magnetic field coupling.

Reducing ringing by adding series resistance in bootstrap circuit and RC snubber.


For this experiment, we use the double sided board with input capacitor location as shown in experiment 2. This setup gives significant radiation from the input loop.

Technical Document Image Preview

Figure 32

As reference measurement, the input supply common mode current was measured without Rboot or RC snubber. The switch waveform shows 5V overshoot with 238MHz ringing frequency. Common mode current in the supply wires shows considerable high frequency noise, see figure 33.

Technical Document Image Preview

Figure 33 : Reference measurement switch waveform and common mode current

RT7297C has a relatively small high side MOSFET (110mΩ), so the impact of adding low values of series resistance to the bootstrap circuit is relatively small. It was found that Rboot needed to more than 20Ω to see any change in the switching waveform. Below scope picture shows the original waveform with 0Ω (reference in grey) and the new waveform when adding 33Ω series resistance, reducing the overshoot to 3V. The impact of this change to the common mode current was very small, hardly measureable in this simple measurement setup.

TEK00015.PNG

Figure 34 : Ringing before and after adding 33Ω Rboot

For determining the RC snubber values, we use the method as described in chapter 5 :

Original fRING = 238MHz. After adding 220pF, fRING becomes 114MHz. CP is thus 220pF/3 = 73pF.

LP can be found from Technical Document Image Preview ; LP = 6.1nH.

RS can be calculated from Technical Document Image Preview ; when we use ξ = 0.5 we get RS = 9.1Ω, we choose 8.2Ω

CS is chosen 4xCP and becomes 330pF.


Waveform before RC snubber Waveform after RC snubber Common mode with snubber
Technical Document Image Preview

Figure 35 : Effect of RC snubber on switch waveform and common mode current


Adding the RC snubber will reduce the common mode current in high frequency range around 5dB.


Rising edge is clean without ringing Falling edge has not changed much
Technical Document Image Preview

Figure 36 : Switching waveform with both solutions : RC snubber 8.2Ω & 330p and 33Ω Rboot


Technical Document Image Preview

Figure 37 : The difference in efficiency when snubber and Rboot are added

As can be seen, Rboot has little effect on efficiency, except a small efficiency drop at higher load.

The RC snubber has more impact on efficiency, especially in the low and mid load range, but still only 1~2% max, which is acceptable. It should be noted that buck converters that operate at higher switching frequency and higher input voltages will show higher losses when snubbers are applied.



7. Buck converter layout tips

A good buck converter layout starts with good planning where to place the key components.

1. In noise sensitive applications, choose buck converters in small, low inductance flip-chip packages.

Technical Document Image Preview

Figure 38 : Different packages will give different input loop area and stray inductance.

2. Identify the VIN and GND node of the switching loop, and place different size input capacitors as close as possible between these nodes, the smallest size capacitor closest to the nodes. This input switching loop carries the very high dI/dt currents, and should be kept as small as possible.

Technical Document Image Preview

Figure 39 : Layout examples with different input capacitor placement

3. Place the output capacitor ground in an area that does not overlap the input capacitor switching loop : this could generate extra high frequency noise in the output voltage.

Technical Document Image Preview

Figure 40

4. The traces from the switching node and BOOT pin carry high dV/dt voltages, and can cause some electric field radiation, so the trace copper area should be kept relatively small, and away from other sensitive signals.

5. The converter small signal section should be away from the high power switching section. The grounding of the small signal section should preferably be a clean low noise ground point. Do not ground small signal section in the area where the VIN decoupling currents or output ripple currents flow, see figure 41 left side.

Technical Document Image Preview

Figure 41

6. Do not use thermal relief in component layout for critical loops, they create extra inductance

See figure 41 right side.

7. When using ground planes, try to keep these planes as solid as possible below the input switching loop. Any trace that cuts the ground plane in this area will reduce the ground plane effectiveness. Signal vias create holes in the ground plane, increasing impedance as well.

8. Vias can be used to connect decoupling capacitors and IC ground to the ground plane, and loop can be shortened. But keep in mind that via inductance can range from 0.1~0.5nH (depending on via thickness and via length), and may increase the total loop inductance. Multiple vias should be used for lower impedance connection.

Technical Document Image Preview

Figure 42

In above example, the additional vias to bottom ground plane do not help a lot in reducing the Cin loop. But in other cases where the top layer loop is long, reducing loop area with vias to the ground plane is quite effective.

9. Note that using the ground plane as return for loop currents will make the ground plane noisy. You can isolate by using a local ground planes, and connect it to the main ground at a point with lowest noise.

10. Ground planes loop shielding effectiveness increases when they are closer to the radiating loop. In multi-layer PCBs, place the solid ground plane on layer 2, directly below the top layer that carries the high power currents.

11. Non shielded inductors generate a lot of magnetic stray fields, which can radiate into other loops or filter components. Semi-shielded or fully shielded inductors should be used in noise sensitive applications and sensitive signals and loops should be kept away from the inductor.



8. Simple EMI probing tools you can build yourself

Measuring EMI compliance often means you have to bring the prototype product to an EMI facility for testing. These are normally 3m sites in anechoic chambers, with special measurement setups using antennas and expensive measurement receivers. The measurement data shows the final results of the complete setup, but it is not always easy to find the root cause of specific radiation frequency emissions from these 3m measurements.

It is possible to do some basic EMI measurements on a prototype product in the lab environment, and examine system blocks separately. These measurements are normally near-field (measuring distance < 0.16λ), so for measuring radiation that originates from current loops, you need a small loop antenna for measuring high frequency magnetic fields. A small electrically shielded loop antenna can be easily made yourself using a length of thin 50Ω coaxial cable : see figure 43.

loop tool.JPG

Figure 43 : Loop antenna construction

The loop antenna can be connected to a spectrum analyzer and by moving the loop over the PCB of your application, you can see which areas emit a lot of high frequency magnetic field. You can also connect the loop antenna to an oscilloscope (terminated in 50Ω) and the oscilloscope will show switching noise levels in certain areas of the PCB. By keeping the loop at a fixed distance and place, and making some changes to circuits/PCB loops, you can check whether radiated noise levels will increase or reduce.

Since radiation from supply wires can contribute considerably to EMI levels, you can also measure the high frequency current in wiring. Not all current probes have sufficient bandwidth to highlight EMI, but a couple of windings on an EMI ferrite core will form a high frequency current transformer. Construction is similar to the loop tool, but now the loop has 3 turns around the ferrite core. See figure 44.

tool transformer.JPG

Figure 44 : High frequency current probe construction

The high frequency current in cables can now be measured by passing a cable through the ferrite core. The current transformer output can be connected to spectrum analyzer or oscilloscope (terminated in 50Ω).

To avoid common mode current flowing from the tested device to the measurement equipment, it is recommended to add a common mode choke in the cable : this can be done by placing a clip-on EMI core with a couple of windings in the cable to the analyzer.

Technical Document Image Preview

Figure 45

Passing both positive and negative supply wire in the same direction though the core will measure the common mode current in the supply wires. Reversing one wire direction will measure differential mode current, see figure 45.

Another handy tool is the current sniffer probe. It is a miniature current transformer with open core, see figure 46. It can be used to measure high frequency currents in copper traces or component pins.

sniffer tool.JPG

Figure 46 : Current sniffer probe construction

It is a bit harder to build yourself. You can grind the open core from a small two holed ferrite bead and add around 4~5 windings, then connect the windings to a coaxial cable. It is best to place the core in the shield opening. When using this tool, you should be aware that it can pick up some electric fields as well. To determine whether the measurement result is magnetic field or electric field pick-up, you can turn the tool 90 degrees on the trace. Magnetic field measurement will almost reduce to zero, electric field pick-up will hardly change.

Technical Document Image Preview

Figure 47 : Current sniffer probe use

The current sniffer probe will let you check how various high frequency currents are flowing through the board and component leads. It can even show how the currents flow through copper planes : You’ll find that a high frequency current in a copper plane will choose the shortest route. Also the eddy currents in the ground plane can be measured.

All measurements in this document were made with the tools described here.



9. Conclusion

Solving EMI can be complex, especially in complete systems without knowing the source of the radiation. With some basic knowledge of critical high frequency signals and loops in switching converters, component and layout behavior at higher frequency and using some simple self-made tools, it is possible to trouble shoot EMI, pin-point the radiation sources and find low cost solutions to reduce radiation.

The major radiation source in buck converters is the converter input switching loop, and this loop should be the first focus point. Switching converters with different package construction can play a role in finding the best component placement for lowest EMI radiation.

Reducing converter switching speed can help reduce EMI, but this should not be the first action to reduce EMI. Shielding by means of ground planes can be effective, as long as the ground planes are solid and as close as possible to the radiating loop. Filtering of input and output supply leads can help to reduce conducted EMI levels.


References :

Fundamentals of Electromagnetic Compatibility 2nd edition, by B. Danker




Next Steps
Richtek Newsletter Subscribe Richtek Newsletter